Zeus
IOPS
3.5-Inch Fibre Channel Solid State Drive 41
MODE (6) SELECT (15h)
The MODE (6) SELECT (15h) command is used to change the device information contained in the
mode pages of a target device. There is a 6-byte version and a 10-byte version. See also: MODE
(10) SELECT (55h).
Table 20. Mode (6) Select (15h) Command
The following MODE PAGES are supported:
Bit
Byte 7 6 5 4 3 2 1 0
0
Operation Code (15h)
1
Logical Unit Number (RSVD) PF Reserved SP
2
Reserved
3
Reserved
4
Parameter List Length
5
Control
Page Description
0x00 Vendor-Specific. Please see the SMART Specification section in this manual.
0x01 Read/Write error recovery. All bits can be changed but only the PER bit is processed.
0x02 Disconnect/Reconnect. On the maximum burst size field (Bytes 10 and 11) can be changed.
0x07 Verify error recovery. All bits can be changed but only the PER bit is processed.
0x19 Fibre Channel Port Control. All bits can be changed but only the DTFD, DLM, RHA, ALWI and
DTOL1 bits are processed.
0x1C Informational Exceptions Control. Please see the SMART Specification section in this manual.
Comentarios a estos manuales