54 Zeus
IOPS
3.5-Inch Fibre Channel Solid State Drive
WRITE (10) SAME (41h) COMMAND
The WRITE (10) SAME (41h) command will request that the device server transfer a single logical
block from the data-out buffer and write the contents of that logical block, with LBDATA and PBDATA
bit modifications, to the specified range of logical block addresses.
Table 36. Write (10) Same (41h) Command
Notes:
1 The WRPROTECT, PBDATA, LBDATA and Group Number fields are not supported. The
command is rejected if any of these bits are set.
2 The Number of Blocks field must be non-zero unless the Logical Block Address is also set
to zero. If the Number of Blocks and the Logical Block Address fields are both zero, then
the 512 bytes of data supplied with the command are written to every user block on the
device.
L
OG SELECT COMMAND (4Ch)
See the SMART Specification section in this manual for details on the LOG SELECT pages that are
supported.
Bit
Byte76543210
0 Operation Code (41h)
1 WRPROTECT Reserved PBDATA LBDATA Obsolete
2 (MSB)
Logical Block Address
3 (LSB)
5 Reserved Group Number
6 (MSB)
Number of Blocks
8 (LSB)
9 Control
Comentarios a estos manuales