3.5-Inch Fibre Channel Solid State Drive 69
LOG PAGE 30H - VENDOR UNIQUE - ERASE ERRORS
This page allows the host to extract the number of flash ERASE commands that have failed to
complete successfully. A percentage is calculated using ERASE Errors/ERASE Commands to form
the basis for a threshold comparison. The Total Bytes Processed field is calculated by multiplying the
Block Size and the Number of Commands. Non-savable parameters are provided since Power On or
Last Parameter Reset. Saved parameters are totals.
Bit
Byte76543210
0 Reserved Page Code = 30h
1 Reserved
2 - 3 Page Length = 0060h
4 - 5 Parameter Code = 0000h (Errors Corrected without Delays)
6 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
7 Parameter Length = 08h
8 - 15 Errors Corrected without Delays
16 - 17 Parameter Code = 0001h (Errors Corrected with Possible Delays)
18 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
19 Parameter Length = 08h
20 - 27 Errors Corrected with Possible Delays
28 - 29 Parameter Code = 0002h (Total Re-Erase)
30 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
31 Parameter Length = 08h
32 - 39 Total Re-Erase
40 - 41 Parameter Code = 0003h (Total Errors Corrected)
42 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
43 Parameter Length = 08h
44 - 51 Total Errors Corrected
52 - 53 Parameter Code = 0004h (Total Times Correction Algorithm Processed)
54 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
55 Parameter Length = 08h
56 - 63 Total Times Correction Algorithm Processed
64 - 65 Parameter Code = 0005h (Total Bytes Processed)
66 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
67 Parameter Length = 08h