70 Zeus
IOPS
3.5-Inch Fibre Channel Solid State Drive
SMART EVENT NOTIFICATION VIA SCSI
The notification and monitoring of SMART events under SCSI systems is controlled using the MODE
SENSE and MODE SELECT commands and pages. The MODE SENSE and MODE SELECT pages
that affect SMART are page 1Ch, the Informational Exceptions control mode page, and page 00h, a
Vendor-Unique page that permits the changing of event thresholds. SMART event notification is
achieved under SCSI via command status bytes and sense information. Page 1Ch permits the host
to select what events are enabled for notification and how those events are notified. Both of these
pages can be requested to return current, default, changing and saved values.
68 - 75 Total Bytes Processed
76 - 77 Parameter Code = 0006h (Total Uncorrected Errors)
78 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
79 Parameter Length = 08h
80 - 87 Total Uncorrected Errors
88 - 89 Parameter Code = 8000h (Vendor Unique - Flash Erase Commands)
90 DU = 0 DS = 1 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
91 Parameter Length = 08h
92 - 99 Flash Erase Commands
100-101 Parameter Code = 8001h (Vendor Unique - Manufacturers Defect Count)
102 DU = 0 DS = 0 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
103 Parameter Length = 08h
104-111 Manufacturers Defect Count
112-113 Parameter Code = 8001h (Vendor Unique - Grown Defect Count)
114 DU = 0 DS = 0 TDS = 0 ETC = 0 TMC = 0 LBIN = 1 LP = 1
115 Parameter Length = 08h
116-123 Grown Defect Count
The saving of values to a non-volatile area is optional within the SCSI
specification. However, the SSD does not currently support the saving
of these pages to a non-volatile area. The saved values are the current
values.
Comentarios a estos manuales