3.5-Inch Fibre Channel Solid State Drive 61
READ ERROR CORRECTION BITS AND COUNT
When blocks are read from the flash, the ECC engine will report which commands were completed
with the aid of ECC correction. The drive will maintain a running count. When this count changes, a
percentage is calculated to provide a rate at which these errors are being generated. The rate is
related to the number of flash Read commands that were issued. The drive also maintains a threshold
value and uses it to report events to the host. To avoid reporting issues with bursts of errors, the
counts will be maintained to reflect what event(s) occurred during the last five (5) minutes of
operation.
WRITE, ERASE AND READ ERROR RATE
The drive will maintain a simple count of when the Write, Erase and Read commands fail. It also
maintains a percentage or rate of failure in relation to the flash Write, Erase or Read commands
issued and compares it against threshold values when the value increases. To avoid reporting issues
with bursts of errors, the counts are maintained to reflect what events occurred during the last five (5)
minutes of operation.
TEMPERATURE
The drives are able to read and check the temperature against a threshold. Drives report the
temperature as defined by the SCSI specification.
EVENT TESTING
The host software can select a TEST mode to check the reporting methods. When this mode is set,
the drive will generate TEST notifications using the selected reporting methods.
DIAGNOSTICS
While not directly related, there are some SMART request and reporting features for drive
diagnostics. These reporting features involve the host requesting that the drive perform either a short
or extended diagnostic. Typically, these are initiated as background tasks that perform media checks.
These media checks verify small or large media areas. The drive is required to hold the information
for the last twenty (20) test, including the completion status. The recorded information is then made
available to the host.
Note: This feature is not supported.
SCSI IMPLEMENTATION
For SCSI, Fibre Channel and SAS connections, there are two topics related to SMART. The first is
implemented using the LOG SENSE and LOG SELECT commands and associated pages. While the
specification for these commands permit the configuration and reporting of threshold parameters,
these features are not supported and are used only to obtain the current counts or readings. As an
alternative, the MODE SENSE and MODE SELECT commands and associated pages specifically
address threshold settings and reporting methods.