3.5-Inch Fibre Channel Solid State Drive
WRITE BUFFER COMMAND (3Bh)
The WRITE BUFFER command is complementary to the READ BUFFER command as a diagnostic
function for testing logical unit memory in the SCSI target device and the integrity of the service
delivery subsystem. Only Mode 2 (Data), Mode 5 (Download Microcode and Save) and Mode 7
(Download Microcode with Offsets and Save) are supported. For all supported modes the
BUFFER_ID and CONTROL fields are not supported and must be set to 0 (zero) and the Allocation
Length must be a multiple of 4 bytes with a maximum value of 2,097,152 (2 megabytes).
Table 32. Write Buffer Command (3Bh)
The only mode fields supported are:
Bit
Byte76543210
0 Operation Code (3Bh)
1 Reserved Mode
2 Buffer ID
3 (MSB)
Buffer Offset
5 (LSB)
6 (MSB)
Parameter List Length
8 (LSB)
9 Control
Mode Value Description
2 02h Data. The OFFSET field is not supported and must be set to 0 (zero).
Where the Allocation Length is greater than 4,096 the buffer will wrap with
only the last 4K of data that was written being returned in response to the
subsequent READ BUFFER command, though this data may be returned
repeatedly. See READ BUFFER 3Ch.
5 05h Download Microcode and Save. The OFFSET field is not supported and
must be set to 0 (zero). Once the firmware has been downloaded and
verified as correct will it be saved and the drive restarted.
7 07h Download Microcode with Offsets and Save. As specified in the ANSI
documentation.