READ (10) LONG (3Eh)
The READ (10) LONG (3Eh) command is used for ECC (Error Correcting Code) data that was written
using the WRITE LONG command. The CORRECT bit is ignored and is always assumed to be set
to 1. If an ECC error is detected, the data is ECC corrected if possible before being returned. The
BYTE TRANSFER LENGTH must be set to 0x218 (536 bytes).
Table 34. Read (10) Long (3Eh) CDB
W
RITE (10) LONG (3Fh)
The WRITE (10) LONG (3Fh) command is complementary to READ (10) LONG (3Eh). It allows for
ECC (Error Correcting Code). The data sent by the initiator will include ECC fields with the data. The
Byte Transfer Length field informs the target device the amount of data that is expected to be returned
when the READ LONG command is used.
Table 35. Write (10) Long (3Fh) CDB
Bit
Byte76543210
0 Operation Code (3Eh)
1 Reserved Correct RelAdr
2 - 5 LBA
6 Reserved
7 - 8 Byte Transfer Length
9 Control
Bit
Byte76543210
0 Operation Code (3Fh)
1 LUN Reserved RelAdr
2 - 5 LBA
6 Reserved
7 - 8 Byte Transfer Length
9 Control